          VFD HS350 Series

          ■Dual analog input

          ■Overcurrent, overvoltage, overload, phase loss, short circuit protection

          ■Simple PLC function

          ■Built-in PID controller

          ■Output voltage regulator AVR function

          ■Built-in EMC filter


          • Product profile
          • Product parameters
          • Data download
          • Optional Accessories

          6[_L_QY7V]ZDZN99~@I6S8W.jpg

          Model

          A

          (mm)

          B

          (mm)

          H

          (mm)

          W

          (mm)

          D

          (mm)

          Mounting holes

          (mm)

          Net Weight

          (KG)

          Gross Weight

          (KG)

          The base

          Installation dimensions

          The peripheral size

          0.4KW  220V

          90

          145

          155

          100

          150

          5

          1.01

          1.22

          0.75KW  220V

          90

          145

          155

          100

          150

          5

          1.01

          1.22

          1.5KW  220V

          90

          145

          155

          100

          150

          5

          1.13

          1.35

          2.2KW  220V

          90

          145

          155

          100

          150

          5

          1.13

          1.35

          3.0KW  220V

          90

          145

          155

          100

          150

          5

          1.17

          1.39

          0.4KW  380V

          90

          145

          155

          100

          150

          5

          1.10

          1.32

          0.75KW  380V

          90

          145

          155

          100

          150

          5

          1.10

          1.32

          1.5KW  380V

          90

          145

          155

          100

          150

          5

          1.13

          1.35

          2.2KW  380V

          90

          145

          155

          100

          150

          5

          1.19

          1.40

          3.0KW  380V

          90

          145

          155

          100

          150

          5

          1.19

          1.40

          4.0KW  380V

          115

          208

          220

          125

          175

          5

          2.30

          2.60

          5.5KW  380V

          115

          208

          220

          125

          175

          5

          2.35

          2.63

          7.5KW  380V

          115

          208

          220

          125

          175

          5

          2.38

          2.65


          RZ]K901V]7HB_{HQ{{%DT[5.jpg

          端子.jpg

          HS-350Technical specifications

          Project

          Specifications

           

           

           

           

           

           

           

           

          The basic function

           

          Frequency

          0-999Hz

          Carrier frequency

          2.0~8.0KHz,The carrier frequency can be automatically adjusted according to the load characteristics

          Frequency resolution

          Analog setting: 0.1% of the highest frequency Digital setting: 0.1Hz

          The control mode

          V/F control

          Steady speed precision

          ±0.5%

          Overload capacity

          G type machine:120% long term 110% 1 minute 150% 5 seconds

          Torque increase

          Manual setting: 0.0 ~ 30.0% of rated output

          Automatic lifting: according to the output current and motor parameters automatically determine the lifting torque

          V/F curve

          Three ways: linear curve, square curve, user - defined V/F curve

          Acceleration curve

          Linear mode

          Dc brake

          Stop DC braking starting frequency: 0.00 ~ upper frequency

          Braking time: 0.0 ~ 100.0s; Braking current: 0.0% ~ 150.0% rated current

          Inching control

          Point frequency range: 0.0Hz ~ 50.0Hz           

          Point acceleration and deceleration time: 0.1 ~ 3600.0s

          Simple PLC, multi - speed operation

          Through built-in PLC or control terminal to achieve up to 16 section speed operation

          Built-in PID

          It can realize the closed-loop control system of process control conveniently

          Motor parameters self-determination

          Without any limitation, automatic detection of parameters can be completed under static and dynamic conditions of the motor to obtain the best control effect

          Overpressure over loss rate control

          Automatic limit of current and voltage during operation to prevent frequent over-current voltage trip

          Wave by wave current limiting function

          Minimize the overcurrent fault to protect the normal operation of the converter

           

           

           

          Personalization function

          Excellent performance

          Vector controlled machine

          Undervoltage inhibition

          For users with low grid voltage and frequent fluctuation of grid voltage, the system can maintain the maximum possible operating time even under the allowable voltage range based on unique algorithms and residual energy allocation strategy

          Wave current limit

          Avoid frequency converter overcurrent failure

          PID control

          Built-in PID controller (preset frequency)

          Automatic voltage regulator operation

          According to the need to choose dynamic voltage regulator, static voltage regulator, unstable voltage three ways to obtain the most stable operation effect

          Acceleration and deceleration time setting

          This parameter can be set continuously from 0.1s to 3600 minutes

          Low noise operation

          The carrier frequency is continuously adjustable from 2.0khz to 8.0khz to minimize motor noise

          Operation function

          Upper and lower frequency setting, frequency jump operation, reverse operation limit, slip frequency compensation, frequency increase and decrease control, fault recovery operation, etc